BITS  | 
    
     
       
     
     		  
     
      
     
     | 
  

This function block allow you to set a bit into a 16-bits word. The bit specified by the input BITN is set when the EN (Enable) pin is active. The REFERENCE field in the property dialog must contain a valid word address specifier.The ENO output reflects the value applied on the EN pin
Property settings
Parameter  | 
Description  | 
REFERENCE  | 
The REFERENCE field in the properties must refer to a word in the table. User can use a direct address identificator %Mx or specify a tag-name  | 
Net plugs
Plug  | 
Description  | 
EN  | 
Enable input  | 
  | 
  | 
ENO  | 
Enable output.The ENO output reflects the value applied on the EN pin  | 
  | 
  | 
BITN  | 
Bit to set within the word (0..15)  |